Coriolis Mass Flowmeter Optimass 1400C
Krohne Marshall
$5303.00$4419.00
Coriolis mass flowmeter for universal applications and process control
Mass, density and volume flow of gases and liquids; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
Also certified for hygienic use
Flange: DN15…100 / ½…4", max. PN100 / ASME Cl 600; many hygienic fittings
3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus, PROFINET, EtherNet/IP™, Bluetooth®
General information
Product type | Flowmeter |
Product family name | OPTIMASS |
Product positioning | For universal applications and process control |
Measurement principle | Coriolis |
Measured media | Liquids, Gases |
Operating conditions
Process pressure | max. 100 barg/ |
Process temperature | -40…+130°C/ |
Materials
Measuring tube | Duplex stainless steel (1.4462/318) |
Process connections
Flange connections | EN (1092-1): DN15…100 |
Hygienic connections | Clamp (DIN 32676): DN25, DN40, DN50, DN80 |
Approvals/Standards
Certificates/Approvals Others | NACE |
Certificates/Approvals Ex | ATEX, IECEx, NEPSI, EAC Ex, cFMus, INMETRO, KCs, UKEX |
Certificates/Approvals Hygienic | FDA, 3A, EHEDG, EC 1935/2004 |
Certificates/Approvals Marine | ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS |
Certificates/Approvals Nuclear | Nuclear qualification on request (e.g. acc. to ASME III, RCC-M/E, etc.) |
Communication
Analogue outputs | 4…20 mA |
Discrete outputs | Limit switches, Pulse, Frequency, Status |
Digital outputs | FOUNDATION™ fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, EtherNet/IP™, PROFINET, Bluetooth |